EN “Industrial valves – Actuators – Part 3: pneumatic part-turn actuators for industrial valves – Basic requirements” • EN “ Industrial. CSN EN – Industrial valves – Actuators – Part 3: Pneumatic part-turn actuators for industrial valves – Basic requirements, Category: Find the most up-to-date version of DIN EN at Engineering

Author: Shajind Mikazuru
Country: Equatorial Guinea
Language: English (Spanish)
Genre: Automotive
Published (Last): 14 January 2006
Pages: 208
PDF File Size: 20.83 Mb
ePub File Size: 12.26 Mb
ISBN: 280-3-37733-737-2
Downloads: 47919
Price: Free* [*Free Regsitration Required]
Uploader: Kajishakar

It is therefore essential that the correct size of actuator is selected together with any associated ancillary equipment.

Connections shall be clearly identified with numbers 2 and 4in accordance with ISO The output drive of part-turn actuators may be an integral part or a removable component to allow it, when necessary, to be machined to suit the driven component of the valve. To qualify a range of actuators, of the same design and of the same action, manufactured under the same process and from the same or equivalent e, the type tests may be carried out on a limited number of sizes by applying ej following rule: This publication does not purport to include all the necessary provisions of a contract.

It is the constant aim of BSI to improve the quality of our products and services. The relationship between air volume V and dimensions of connections “2” and “4” are given ej guidelines.

The position, location, orientation and form of the pressure connections shall be established by the manufacturer. Pneumatic part-turn actuatorsfor industrial valves — BasicrequirementsICS A version in any other language made by translation under the respons eb of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.

If the slot is used as a position indicator it shall be parallel to the pipe axis when the valve is open. The position, location, orientation and form of the 15714- connections shall be established by the manufacturer.

  BYL JSEM MENGELEHO ASISTENTEM PDF

RevisionsBritish Standards are updated by amendment or revision. The aim of these guidelines is to provide 1571-43 clear understanding of the torque requirements and what parameters affect the correct actuator selection. Except aspermitted under the Copyright, Designs and Patents Act no extract maybe reproduced, stored in a retrieval system or transmitted in any form or by anymeans — electronic, photocopying, recording or otherwise — without prior 155714-3 Grouppermission from BSI.

Compliance with a British Standard cannot confer immunityfrom legal obligations. External actuator leakage rates at room temperature shall be measured and recorded at the beginning and at the end of the test, at both end of travel positions. This is usually associated with critical valve rn e.

Buildings or areas with almost permanent condensation and with high pollution. Production rooms with high humidity and some air pollution, e. Pneumatic part-turn actuators for industrial valves — Basic requirements www. C5-I very high — industrial Industrial areas with high humidity and aggressive atmosphere.

General introduction and designation system ISO It is incorporated by Royal Charter. Im 2 Immersed in sea or brackish water Harbour areas and offshore structures.

It includes guidelines, recommendations and methods for enclosure and corrosion protection, control and testing. 15741-3

Valve actuator family of standards EN -1,-2,-3 and -4

Pressure Shell testWhen required 3 4. Industrial valves – Measurement, test and em procedures for fugitive emissions – Part 1: Except as permitted under the Copyright, Designs and Patents Act no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means — electronic, photocopying, recording or otherwise — without prior written permission from BSI.

The final leakage values at 0,55 MPa 5,5 bar shall not exceed the rates given in Table A. It is the constant aim of BSI to improve the quality of our products and services. The price of the Standard included all amendments and correcturs. The actuator manufacturer’s technical documentation shall specify the corrosion protection category according to Table 2.

  EXERCICES TRIGONALISATION PDF

Valve actuator family of standards EN 15714 -1,-2,-3 and -4

Up-to-date lists and bibliographical references concerning such national standards may 155714-3 obtained on application to the CEN Management Centre or to any CEN member. Dimensions, tolerances and designation ISO Compliance with a British Standard cannot confer immunity from legal obligations.

Tests, test procedures and acceptance criteria – Supplementary requirements.

The mounting of positioners and signal devices to part-turn actuators is also possible with a bracket with dimensions according to the E 7 and Figure 5.

The following is optional: It includes guidelines, recommendations and methods for enclosure and corrosion protection, control and testing. When pressurised, direction of movement shall be in accordance with Table 3 below, unless otherwise specified.

CSN EN 15714-3

The type dn to be performed shall be those given in Table 8. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover.

The actuator manufacturer’s technical documentation shall specify the corrosion protection category according to Table 2. Please insert your email, we will inform immediately after publishing this standard include — discount code. At the maximum supply pressure, the 15714- output torque of the selected actuator shall not exceed the maximum allowable valve stem torque limitation MAST.

For details of these and other benefits contact Membership Administration. Hydraulic part-turn actuators for industrial valves – Basic requirements. Details and advice can be obtained from the Copyright and Licensing Manager. The maximum allowable pressure shall be at least 0,8 MPa 8 barunless otherwise specified.